Moseley Plot and Absorption Edges
https://xraytools.com/moseley
Where an element’s characteristic X-ray lines fall, from the one relation that connects them all: the square root of the line energy is linear in atomic number. The straight line is fitted to this site’s own six anodes, so you can see what it is worth before you use it.
- You supply
- An element symbol (
Ni) or an atomic number (28). Nothing else — a characteristic line is a property of the element alone. - Reading it
- A predicted line is not a measured one: the fit is good to about a per cent from roughly Z = 20 to 50 and drifts several per cent by tungsten. Where this site holds the measurement it is printed beside the prediction. Moseley’s law fits the characteristic lines and predicts no absorption edge: the edge energies here are tabulated, and the bracket between two elements is a check on them rather than a substitute for them.
Worked examples: nickel, the filter for copper · zirconium, the filter for molybdenum · tungsten, far outside the fit
Earlier on the path: X-ray Tube Spectrum Next on the path: Absorption Coefficient Calculator On Choosing the radiation, step 2 of 4
See also: X-ray Tube Spectrum · Absorption Coefficient Calculator
Teaching with this page
- Objective
- After this page a learner can name the filter for an anode and say what makes that element and no other the right one.
- Start from
- this worked example
- Ask first
- Nickel is the filter for a copper tube. Would nickel also filter a molybdenum tube?
- Watch for
- “Yes — nickel absorbs X-rays whatever produced them”
- Then
- Absorption Coefficient Calculator
Check yourself: Nickel is the filter for a copper tube. Would nickel also filter a molybdenum tube?
No — a filter is chosen for one anode, not for X-rays in general Yes — nickel absorbs X-rays whatever produced them
A filter works because its K absorption edge falls between the anode’s two lines. Nickel’s edge is at 8.33 keV, which sits between copper’s Kβ at 8.91 and Kα at 8.04 — so Kβ is on the strongly absorbed side and Kα is not. Molybdenum’s lines are at 19.61 and 17.44 keV, both far above nickel’s edge, where nickel absorbs the two almost equally and improves nothing. Molybdenum’s filter is zirconium, edge 18.00 keV.
Input
Predicted lines for Cu (Z = 29)
| Line | E / keV | λ / Å | measured λ / Å | difference |
|---|---|---|---|---|
| Kα | 8.05950 | 1.53836 | 1.541838 | −0.23% |
| Kα1 | 8.06803 | 1.53673 | 1.540562 | −0.25% |
| Kα2 | 8.04250 | 1.54161 | 1.544390 | −0.18% |
| Kβ | 8.93469 | 1.38767 | 1.392218 | −0.33% |
The straight line is fitted to this site’s own six anodes, Z = 24 to 47, and reproduces all of their measured wavelengths to better than 0.16% in . It stays inside about 1% from roughly Z = 20 to Z = 50. Further out it is an extrapolation and the error grows: against Z is not exactly straight, because screening is incomplete and relativistic corrections rise as Z4, so by tungsten (Z = 74) the predicted Kα is several per cent low. A predicted line is not a measured one; where this site has the measurement it is printed beside the prediction.
Moseley’s law
Filled points are the measured Kα energies of the six anodes; the dashed line is the least-squares fit through them.
| Anode | Z | measured λ / Å | fitted | residual | |
|---|---|---|---|---|---|
| Cr | 24 | 2.29100 | 2.32633 | 2.32268 | 0.157% |
| Fe | 26 | 1.937355 | 2.52976 | 2.52918 | 0.023% |
| Co | 27 | 1.790260 | 2.63163 | 2.63243 | 0.030% |
| Cu | 29 | 1.541838 | 2.83572 | 2.83893 | 0.113% |
| Mo | 42 | 0.710730 | 4.17668 | 4.18116 | 0.107% |
| Ag | 47 | 0.560871 | 4.70166 | 4.69741 | 0.091% |
Bohr’s model predicts m = = 0.10102 and σ = 1 for Kα — one 1s electron screening the other. Fitted over the four light anodes alone (Cr to Cu), Kα gives m = 0.10188 and σ = 1.17, close to the N − 1 Moseley wrote. Including Mo and Ag bends the line and pulls σ to 1.50 — the value the fit above this table used. Nothing is wrong with either fit: the law is an excellent approximation over a limited span of Z, not an identity. Moseley’s own K series ran from aluminium to silver, his L series from zirconium to gold (Phil. Mag. 27, 703, 1914), and he noted that the lines of very short wavelength “gradually diverge” from the straight line — the bend that Mo and Ag put into the fit above.
How this is calculated
Moseley’s law: the square root of the photon energy of a characteristic line is linear in atomic number.
Fitted by least squares to the six anodes this site carries, for the Kα line:
The K absorption edge
Walk up the periodic table at a fixed wavelength and μ/ρ climbs steadily — more electrons, more absorption. At each of these six Kα1 wavelengths it does that everywhere except at one place, where it falls by a factor near seven between neighbouring elements. That is the K absorption edge, and the direction is worth stating in the variable that is moving. Walking up Z at a fixed wavelength: for the lighter element the edge lies below the photon’s energy, so the photon can eject a 1s electron and the K shell contributes; one element heavier the edge has risen past it, the photon can no longer reach the 1s electron, and the K shell stops absorbing altogether. Said in energy at a fixed element, which is how an edge is usually quoted, that is the same fact the other way round: a photon above the edge energy ionises the K shell and one below it cannot.
| Radiation | Z | Kα1 / Å | E / keV | edge lies between | their K edges / keV | μ/ρ either side | drop |
|---|---|---|---|---|---|---|---|
| Ag Kα1 | 47 | 0.5594075 | 22.163 | Ru (44) and Rh (45) | 22.117 < 22.163 < 23.220 | 66.0996 → 11.9334 | ×5.5 |
| Mo Kα1 | 42 | 0.709300 | 17.480 | Y (39) and Zr (40) | 17.038 < 17.480 < 17.998 | 97.2508 → 15.57 | ×6.2 |
| Cu Kα1 | 29 | 1.540562 | 8.048 | Co (27) and Ni (28) | 7.709 < 8.048 < 8.333 | 322.096 → 46.925 | ×6.9 |
| Co Kα1 | 27 | 1.788965 | 6.930 | Mn (25) and Fe (26) | 6.539 < 6.930 < 7.112 | 392.229 → 53.8726 | ×7.3 |
| Fe Kα1 | 26 | 1.936042 | 6.404 | Cr (24) and Mn (25) | 5.989 < 6.404 < 6.539 | 443.942 → 57.5063 | ×7.7 |
| Cr Kα1 | 24 | 2.28970 | 5.415 | Ti (22) and V (23) | 4.966 < 5.415 < 5.465 | 557.253 → 70.0046 | ×8.0 |
The drop is found in the coefficients and the edge energies are tabulated separately, so the last two columns are a check rather than a restatement: the Kα1 photon energy has to fall between the two edges named, and it does, on every row. The rows are drawn for Kα1 and not for the weighted mean of the doublet because the mean is an energy no photon has, and Kα1 is the more energetic component: an edge above it is above Kα2 as well. Kα2 lies between the same two edges on every row except Ag, where the K edge of Ru at 22.117 keV lies between Kα2 (21.991 keV) and Kα1 (22.163 keV) — so that element absorbs one component of the doublet through its K shell and not the other. Nothing here is predicted — the Moseley fit above is over emission lines, and it is not continued to an absorption edge.
A Kβ filter is a foil whose own K edge lies between the anode’s Kα and Kβ: Kβ is the more energetic, so it is absorbed by ejecting the foil’s 1s electrons, while Kα falls short of the edge and passes much less attenuated. The jump above names the lightest element whose edge clears Kα1, and with it the whole doublet. The conventional filter is that element or the next one heavier — nickel for copper, zirconium for molybdenum, rhodium or palladium for silver. Ag is the case that shows why the rule has to be stated for Kα1 and not for the mean of the doublet: Ru’s K edge is 126 eV above Kα2 and 46 eV below Kα1, so a foil of it would pass the weaker component and absorb the stronger. The lightest element that clears both is Rh.
Where this comes from
- The high-frequency spectra of the elements
H. G. J. Moseley, Philos. Mag. 1913, 26, 1024–1034 · doi:10.1080/14786441308635052
The law this page plots, and the paper that turned atomic number from a position in a list into a measurable quantity. - The high-frequency spectra of the elements. Part II
H. G. J. Moseley, Philos. Mag. 1914, 27, 703–713 · doi:10.1080/14786440408635141
The second half, extending the series and settling the places in the periodic table that were still disputed.